46x83x18 ft

46x83x18 ft

Comfortably accommodates 232 people, based on our standard of 12ft2 per person.

SHELTER

ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
1-m diameter columns
11 main assembly columns
6 column vertical end unit design
FlyShelter cover that protects the interior from ambient environment.
Fabric used: PVC coated polyester.
Custom logos in price. Custom fabric colors possible.
16-oz fabric
Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 4 vents
Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
TetherstrapsStandard nylon tetherstraps.5.08-cm wide
Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.46 pin anchors for ground, or
46 concrete drop-in anchors
Blast DoorsStandard door layout for required building codes.Four 1.82-m doors positioned on the corners
LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.12 lights

OPTIONS

Blast DoorsOther door layouts and sizes are possible.Various
Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.3,936
Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

ADDITIONAL INFORMATION

Internal AreaInternal area of shelter259 m2
Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.17.7 m x 36.6 m
Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.18.7 m x 36.7 m
Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 19.2 m x 31.1 m
OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.232 people
Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.21.04 Amps
Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

SHELTER

ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
3.28-ft diameter columns
11 main assembly columns
6 column vertical end unit design
FlyShelter cover that protects the interior from ambient environment.
Fabric used: PVC coated polyester.
Custom logos in price. Custom fabric colors possible.
16-oz fabric
Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 4 vents
Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
TetherstrapsStandard nylon tetherstraps.2-in wide
Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.46 pin anchors for ground, or
46 concrete drop-in anchors
Blast DoorsStandard door layout for required building codes.Four 72-in doors positioned on the corners
LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.12 lights

OPTIONS

Blast DoorsOther door layouts and sizes are possible.Various
Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.3,936
Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

ADDITIONAL INFORMATION

Internal AreaInternal area of shelter2,787 ft2
Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.58 ft x 120 ft
Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.62 ft x 121 ft
Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 63 ft x 102 ft
OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.232 people
Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.21.04 Amps
Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

LOOKING FOR SOMETHING ELSE?

Review all of our standard sizes and configurations.

CALL US TODAY

1 (877) 772-7734 (TOLL FREE)
SALES@DYNAMICAIRSHELTERS.COM

LEAVE US A MESSAGE

    46x95x18 ft

    46x95x18 ft

    Comfortably accommodates 279 people, based on our standard of 12ft2 per person.

    SHELTER

    ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
    1-m diameter columns
    13 main assembly columns
    6 column vertical end unit design
    FlyShelter cover that protects the interior from ambient environment.
    Fabric used: PVC coated polyester.
    Custom logos in price. Custom fabric colors possible.
    16-oz fabric
    Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
    Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
    Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
    PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
    HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 6 vents
    Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
    TetherstrapsStandard nylon tetherstraps.5.08-cm wide
    Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.50 pin anchors for ground, or
    50 concrete drop-in anchors
    Blast DoorsStandard door layout for required building codes.Four 1.82-m doors positioned on the corners
    LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.14 lights

    OPTIONS

    Blast DoorsOther door layouts and sizes are possible.Various
    Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.4,702
    Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
    Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
    Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
    Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
    Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

    ADDITIONAL INFORMATION

    Internal AreaInternal area of shelter311 m2
    Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.17.7 m x 40.2 m
    Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.18.7 m x 40.3 m
    Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 19.2 m x 34.7 m
    OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.279 people
    Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.22.68 Amps
    Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
    Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
    FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

    SHELTER

    ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
    3.28-ft diameter columns
    13 main assembly columns
    6 column vertical end unit design
    FlyShelter cover that protects the interior from ambient environment.
    Fabric used: PVC coated polyester.
    Custom logos in price. Custom fabric colors possible.
    16-oz fabric
    Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
    Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
    Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
    PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
    HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 6 vents
    Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
    TetherstrapsStandard nylon tetherstraps.2-in wide
    Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.50 pin anchors for ground, or
    50 concrete drop-in anchors
    Blast DoorsStandard door layout for required building codes.Four 72-in doors positioned on the corners
    LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.14 lights

    OPTIONS

    Blast DoorsOther door layouts and sizes are possible.Various
    Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.4,702
    Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
    Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
    Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
    Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
    Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

    ADDITIONAL INFORMATION

    Internal AreaInternal area of shelter3,348 ft2
    Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.58 ft x 132 ft
    Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.62 ft x 132 ft
    Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 63 ft x 114 ft
    OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.279 people
    Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.22.68 Amps
    Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
    Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
    FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

    LOOKING FOR SOMETHING ELSE?

    Review all of our standard sizes and configurations.

    CALL US TODAY

    1 (877) 772-7734 (TOLL FREE)
    SALES@DYNAMICAIRSHELTERS.COM

    LEAVE US A MESSAGE

      62x82x24 ft

      62x82x24 ft

      Comfortably accommodates 302 people, based on our standard of 12ft2 per person.

      SHELTER

      ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
      1.3-m diameter columns
      9 main assembly columns
      Concentric end units
      FlyShelter cover that protects the interior from ambient environment.
      Fabric used: PVC coated polyester.
      Custom logos in price. Custom fabric colors possible.
      22-oz fabric
      Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
      Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
      Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
      PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
      HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 4 vents
      Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
      TetherstrapsStandard nylon tetherstraps.5.08-cm wide
      Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.50 pin anchors for ground, or
      50 concrete drop-in anchors
      Blast DoorsStandard door layout for required building codes.Two 1.82-m doors per shelter, positioned on center of each end unit
      Four 0.91-m doors positioned on the corners
      LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.20 lights

      OPTIONS

      Blast DoorsOther door layouts and sizes are possible.Various
      Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.4,864
      Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
      Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
      Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
      Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
      Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

      ADDITIONAL INFORMATION

      Internal AreaInternal area of shelter336 m2
      Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.22.6 m x 30.1m
      Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.23.6 m x 33.4 m
      Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 24.1 m x 30.4 m
      OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.302 people
      Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.27.6 Amps
      Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
      Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
      FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

      SHELTER

      ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
      4.27-ft diameter columns
      9 main assembly columns
      Concentric end units
      FlyShelter cover that protects the interior from ambient environment.
      Fabric used: PVC coated polyester.
      Custom logos in price. Custom fabric colors possible.
      22-oz fabric
      Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
      Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
      Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
      PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
      HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 4 vents
      Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
      TetherstrapsStandard nylon tetherstraps.2-in wide
      Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.50 pin anchors for ground, or
      50 concrete drop-in anchors
      Blast DoorsStandard door layout for required building codes.Two 72-in doors per shelter, positioned on center of each end unit
      Four 36-in doors positioned on the corners
      LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.20 lights

      OPTIONS

      Blast DoorsOther door layouts and sizes are possible.Various
      Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.4,864
      Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
      Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
      Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
      Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
      Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

      ADDITIONAL INFORMATION

      Internal AreaInternal area of shelter3,624 ft2
      Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.74 ft x 99 ft
      Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.78 ft x 110 ft
      Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 79 ft x 99.6 ft
      OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.302 people
      Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.27.6 Amps
      Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
      Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
      FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

      LOOKING FOR SOMETHING ELSE?

      Review all of our standard sizes and configurations.

      CALL US TODAY

      1 (877) 772-7734 (TOLL FREE)
      SALES@DYNAMICAIRSHELTERS.COM

      LEAVE US A MESSAGE

        62x95x24 ft

        62x95x24 ft

        Comfortably accommodates 357 people, based on our standard of 12ft2 per person.

        SHELTER

        ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
        1.3-m diameter columns
        11 main assembly columns
        Concentric end units
        FlyShelter cover that protects the interior from ambient environment.
        Fabric used: PVC coated polyester.
        Custom logos in price. Custom fabric colors possible.
        22-oz fabric
        Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
        Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
        Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
        PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
        HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 4 vents
        Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
        TetherstrapsStandard nylon tetherstraps.5.08-cm wide
        Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.50 pin anchors for ground, or
        50 concrete drop-in anchors
        Blast DoorsStandard door layout for required building codes.Two 1.82-m doors per shelter, positioned on center of each end unit
        Four 0.91-m doors positioned on the corners
        LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.24 lights

        OPTIONS

        Blast DoorsOther door layouts and sizes are possible.Various
        Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.5,632
        Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
        Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
        Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
        Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
        Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

        ADDITIONAL INFORMATION

        Internal AreaInternal area of shelter398 m2
        Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.22.6 m x 36.1 m
        Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.23.6 m x 37 m
        Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 24.1 m x 34.2 m
        OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.357 people
        Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.30.88 Amps
        Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
        Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
        FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

        SHELTER

        ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
        4.27-ft diameter columns
        11 main assembly columns
        Concentric end units
        FlyShelter cover that protects the interior from ambient environment.
        Fabric used: PVC coated polyester.
        Custom logos in price. Custom fabric colors possible.
        22-oz fabric
        Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
        Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
        Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
        PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
        HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 4 vents
        Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
        TetherstrapsStandard nylon tetherstraps.2-in wide
        Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.50 pin anchors for ground, or
        50 concrete drop-in anchors
        Blast DoorsStandard door layout for required building codes.Two 72-in doors per shelter, positioned on center of each end unit
        Four 36-in doors positioned on the corners
        LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.24 lights

        OPTIONS

        Blast DoorsOther door layouts and sizes are possible.Various
        Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.5,632
        Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
        Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
        Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
        Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
        Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

        ADDITIONAL INFORMATION

        Internal AreaInternal area of shelter4,290 ft2
        Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.74 ft x 119 ft
        Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.77.3 ft x 121.3 ft
        Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 79 ft x 112 ft
        OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.357 people
        Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.30.88 Amps
        Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
        Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
        FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

        LOOKING FOR SOMETHING ELSE?

        Review all of our standard sizes and configurations.

        CALL US TODAY

        1 (877) 772-7734 (TOLL FREE)
        SALES@DYNAMICAIRSHELTERS.COM

        LEAVE US A MESSAGE

          46x132x18 ft

          46x132x18 ft

          Comfortably accommodates 395 people, based on our standard of 12ft2 per person.

          SHELTER

          ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
          1-m diameter columns
          19 main assembly columns
          6 column vertical end unit design
          FlyShelter cover that protects the interior from ambient environment.
          Fabric used: PVC coated polyester.
          Custom logos in price. Custom fabric colors possible.
          16-oz fabric
          Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
          Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
          Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
          PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
          HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 8 vents
          Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
          TetherstrapsStandard nylon tetherstraps.5.08-cm wide
          Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.62 pin anchors for ground, or
          62 concrete drop-in anchors
          Blast DoorsStandard door layout for required building codes.Four 1.82-m doors positioned on the corners
          One 1.82-m side egress door
          LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.24 lights

          OPTIONS

          Blast DoorsOther door layouts and sizes are possible.Various
          Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.6,430
          Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
          Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
          Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
          Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
          Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

          ADDITIONAL INFORMATION

          Internal AreaInternal area of shelter440 m2
          Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.17.7 m x 50.9 m
          Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.18.7 m x 51 m
          Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 19.2 m x 45.4 m
          OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.395 people
          Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.27.2 Amps
          Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
          Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
          FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

          SHELTER

          ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
          3.28-ft diameter columns
          19 main assembly columns
          6 column vertical end unit design
          FlyShelter cover that protects the interior from ambient environment.
          Fabric used: PVC coated polyester.
          Custom logos in price. Custom fabric colors possible.
          16-oz fabric
          Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
          Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
          Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
          PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
          HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 8 vents
          Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.2 continual blowers
          TetherstrapsStandard nylon tetherstraps.2-in wide
          Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.62 pin anchors for ground, or
          62 concrete drop-in anchors
          Blast DoorsStandard door layout for required building codes.Four 72-in doors positioned on the corners
          One 72-in side egress door
          LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.24 lights

          OPTIONS

          Blast DoorsOther door layouts and sizes are possible.Various
          Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.6,430
          Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
          Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
          Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
          Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
          Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

          ADDITIONAL INFORMATION

          Internal AreaInternal area of shelter4,742 ft2
          Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.58 ft x 167 ft
          Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.62 ft x 167 ft
          Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 63 ft x 149 ft
          OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.395 people
          Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.27.2 Amps
          Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
          Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
          FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

          LOOKING FOR SOMETHING ELSE?

          Review all of our standard sizes and configurations.

          CALL US TODAY

          1 (877) 772-7734 (TOLL FREE)
          SALES@DYNAMICAIRSHELTERS.COM

          LEAVE US A MESSAGE

            62x123x24 ft

            62x123x24 ft

            Comfortably accommodates 490 people, based on our standard of 12ft2 per person.

            SHELTER

            ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
            1.3-m diameter columns
            14 main assembly columns
            Concentric end units
            FlyShelter cover that protects the interior from ambient environment.
            Fabric used: PVC coated polyester.
            Custom logos in price. Custom fabric colors possible.
            22-oz fabric
            Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
            Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
            Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
            PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
            HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 6 vents
            Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
            TetherstrapsStandard nylon tetherstraps.5.08-cm wide
            Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.62 pin anchors for ground, or
            62 concrete drop-in anchors
            Blast DoorsStandard door layout for required building codes.Two 1.82-m doors per shelter, positioned on center of each end unit
            Four 0.91-m doors positioned on the corners
            One 1.82-m side egress door
            LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.30 lights

            OPTIONS

            Blast DoorsOther door layouts and sizes are possible.Various
            Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.7,680
            Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
            Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
            Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
            Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
            Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

            ADDITIONAL INFORMATION

            Internal AreaInternal area of shelter546 m2
            Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.22.6 m x 246.4 m
            Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.23.6 m x 45.6 m
            Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 24.1 m x 43.2 m
            OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.490 people
            Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.35.2 Amps
            Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
            Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
            FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

            SHELTER

            ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
            4.27-ft diameter columns
            14 main assembly columns
            Concentric end units
            FlyShelter cover that protects the interior from ambient environment.
            Fabric used: PVC coated polyester.
            Custom logos in price. Custom fabric colors possible.
            22-oz fabric
            Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
            Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
            Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
            PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
            HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 6 vents
            Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
            TetherstrapsStandard nylon tetherstraps.2-in wide
            Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.62 pin anchors for ground, or
            62 concrete drop-in anchors
            Blast DoorsStandard door layout for required building codes.Two 72-in doors per shelter, positioned on center of each end unit
            Four 36-in doors positioned on the corners
            One 72-in side egress door
            LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.30 lights

            OPTIONS

            Blast DoorsOther door layouts and sizes are possible.Various
            Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.7,680
            Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
            Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
            Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
            Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
            Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

            ADDITIONAL INFORMATION

            Internal AreaInternal area of shelter5,880 ft2
            Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.74 ft x 152 ft
            Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.77 ft x 150 ft
            Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 79 ft x 142 ft
            OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.490 people
            Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.35.2 Amps
            Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
            Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
            FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

            LOOKING FOR SOMETHING ELSE?

            Review all of our standard sizes and configurations.

            CALL US TODAY

            1 (877) 772-7734 (TOLL FREE)
            SALES@DYNAMICAIRSHELTERS.COM

            LEAVE US A MESSAGE

              62x152x24 ft

              62x152x24 ft

              Comfortably accommodates 616 people, based on our standard of 12ft2 per person.

              SHELTER

              ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
              1.3-m diameter columns
              18 main assembly columns
              Concentric end units
              FlyShelter cover that protects the interior from ambient environment.
              Fabric used: PVC coated polyester.
              Custom logos in price. Custom fabric colors possible.
              22-oz fabric
              Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
              Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
              Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
              PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
              HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 8 vents
              Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
              TetherstrapsStandard nylon tetherstraps.5.08-cm wide
              Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.70 pin anchors for ground, or
              70 concrete drop-in anchors
              Blast DoorsStandard door layout for required building codes.Two 1.82-m doors per shelter, positioned on center of each end unit
              Four 0.91-m doors positioned on the corners
              One 1.82-m side egress door
              LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.36 lights

              OPTIONS

              Blast DoorsOther door layouts and sizes are possible.Various
              Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.9,472
              Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
              Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
              Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
              Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
              Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

              ADDITIONAL INFORMATION

              Internal AreaInternal area of shelter687 m2
              Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.22.6 m x 55 m
              Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.23.5 m x 54.2 m
              Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 24.1 m x 51.8 m
              OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.616 people
              Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.53 Amps
              Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
              Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
              FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

              SHELTER

              ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
              4.27-ft diameter columns
              18 main assembly columns
              Concentric end units
              FlyShelter cover that protects the interior from ambient environment.
              Fabric used: PVC coated polyester.
              Custom logos in price. Custom fabric colors possible.
              22-oz fabric
              Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
              Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
              Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
              PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
              HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 8 vents
              Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
              TetherstrapsStandard nylon tetherstraps.2-in wide
              Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.70 pin anchors for ground, or
              70 concrete drop-in anchors
              Blast DoorsStandard door layout for required building codes.Two 72-in doors per shelter, positioned on center of each end unit
              Four 36-in doors positioned on the corners
              One 72-in side egress door
              LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.36 lights

              OPTIONS

              Blast DoorsOther door layouts and sizes are possible.Various
              Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.9,472
              Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
              Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
              Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
              Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
              Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

              ADDITIONAL INFORMATION

              Internal AreaInternal area of shelter7,395 ft2
              Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.74 ft x 181 ft
              Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.77 ft x 178 ft
              Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 79 ft x 170 ft
              OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.616 people
              Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.53 Amps
              Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
              Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
              FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

              LOOKING FOR SOMETHING ELSE?

              Review all of our standard sizes and configurations.

              CALL US TODAY

              1 (877) 772-7734 (TOLL FREE)
              SALES@DYNAMICAIRSHELTERS.COM

              LEAVE US A MESSAGE

                78x182x26 ft

                78x182x26 ft

                Comfortably accommodates 932 people, based on our standard of 12ft2 per person.

                SHELTER

                ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
                1.5-m diameter columns
                18 main assembly columns
                Concentric end units
                FlyShelter cover that protects the interior from ambient environment.
                Fabric used: PVC coated polyester.
                Custom logos in price. Custom fabric colors possible.
                22-oz fabric
                Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
                Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
                Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
                PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
                HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 12 vents
                Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
                TetherstrapsStandard nylon tetherstraps.5.08-cm wide
                Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.64 pin anchors for ground, or
                64 concrete drop-in anchors
                Blast DoorsStandard door layout for required building codes.Four 1.82-m doors positioned on the corners
                One 1.82-m side egress door
                LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.50 lights

                OPTIONS

                Blast DoorsOther door layouts and sizes are possible.Various
                Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.14,208
                Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
                Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
                Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
                Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
                Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

                ADDITIONAL INFORMATION

                Internal AreaInternal area of shelter1,039 m2
                Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.27 m x 63.6 m
                Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.30 m x 63.6 m
                Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 29 m x 60.7 m
                OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.932 people
                Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.62.4 Amps
                Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
                Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
                FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

                SHELTER

                ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
                4.92-ft diameter columns
                18 main assembly columns
                Concentric end units
                FlyShelter cover that protects the interior from ambient environment.
                Fabric used: PVC coated polyester.
                Custom logos in price. Custom fabric colors possible.
                22-oz fabric
                Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
                Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
                Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
                PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
                HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 12 vents
                Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
                TetherstrapsStandard nylon tetherstraps.2-in wide
                Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.64 pin anchors for ground, or
                64 concrete drop-in anchors
                Blast DoorsStandard door layout for required building codes.Four 72-in doors positioned on the corners
                One 72-in side egress door
                LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.50 lights

                OPTIONS

                Blast DoorsOther door layouts and sizes are possible.Various
                Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.14,208
                Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
                Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
                Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
                Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
                Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

                ADDITIONAL INFORMATION

                Internal AreaInternal area of shelter11,192 ft2
                Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.89 ft x 198.6 ft
                Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.99 ft x 209 ft
                Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 95 ft x 199 ft
                OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.932 people
                Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.62.4 Amps
                Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
                Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
                FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

                LOOKING FOR SOMETHING ELSE?

                Review all of our standard sizes and configurations.

                CALL US TODAY

                1 (877) 772-7734 (TOLL FREE)
                SALES@DYNAMICAIRSHELTERS.COM

                LEAVE US A MESSAGE