62x152x24 ft

Comfortably accommodates 616 people, based on our standard of 12ft2 per person.

SHELTER

ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
1.3-m diameter columns
18 main assembly columns
Concentric end units
FlyShelter cover that protects the interior from ambient environment.
Fabric used: PVC coated polyester.
Custom logos in price. Custom fabric colors possible.
22-oz fabric
Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.55.88-cm HVAC inlets, 8 vents
Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
TetherstrapsStandard nylon tetherstraps.5.08-cm wide
Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.70 pin anchors for ground, or
70 concrete drop-in anchors
Blast DoorsStandard door layout for required building codes.Two 1.82-m doors per shelter, positioned on center of each end unit
Four 0.91-m doors positioned on the corners
One 1.82-m side egress door
LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.36 lights

OPTIONS

Blast DoorsOther door layouts and sizes are possible.Various
Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.9,472
Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.9-kg minimum fire extinguisher and stand.
Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

ADDITIONAL INFORMATION

Internal AreaInternal area of shelter687 m2
Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.22.6 m x 55 m
Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.23.5 m x 54.2 m
Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 24.1 m x 51.8 m
OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.616 people
Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.53 Amps
Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.130 kph
Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.0.42-kg/m2 natural snow load capacity.
FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).

SHELTER

ColumnsInflatable leg assembly includes a main column assembly with end units on either side. Columns are low pressure welded fabric structural columns. Fabric used: PVC coated polyester.31.5-oz fabric
4.27-ft diameter columns
18 main assembly columns
Concentric end units
FlyShelter cover that protects the interior from ambient environment.
Fabric used: PVC coated polyester.
Custom logos in price. Custom fabric colors possible.
22-oz fabric
Fly CablesComplete set of fly cables to limit fabric movement in heavy wind conditions.Included
Exterior SkirtFull perimeter removable fabric skirt to seal shelter to ground or flooring. Acts as a rain guard to shed water away from foundation area.Included
Interior CurtainComplete interior curtain to provide additional insulation and provide finished interior look. Hides columns, blowers, and hoses from view. Fabric used: PVC coated nylonIncluded
PlenumInterior HVAC distribution plenum with manually adjustable screen vents for improved air control.Included
HVAC InletsHVAC inlets with matching return vent. Provides the required ventilation to the shelter for occupation.22-in HVAC inlets, 8 vents
Inflation SystemInflation system includes inflation blowers for quick installation. Includes long term continual blowers and inflation harness. Includes Air On Demand system to control air flow, all valves, and power cords.4 continual blowers
TetherstrapsStandard nylon tetherstraps.2-in wide
Anchoring SystemStandard ground pin anchors or anchors for concrete blocks.70 pin anchors for ground, or
70 concrete drop-in anchors
Blast DoorsStandard door layout for required building codes.Two 72-in doors per shelter, positioned on center of each end unit
Four 36-in doors positioned on the corners
One 72-in side egress door
LightsLong tube connector florescent lights for adequate luminescence based on regular occupation. Lighting is typically not required for shelters not regularly occupied.36 lights

OPTIONS

Blast DoorsOther door layouts and sizes are possible.Various
Stage FlooringRaised stage flooring. Flooring composed of 4x4 all wood marine grade panels and galvanized steel frame. Blast resistant. Vapour barrier required to prevent moisture contact - sold separately.9,472
Vapour BarrierFabric sheet used below flooring to prevent moisture contact. Not required unless flooring is purchased.
Emergency Exit SystemEmergency exit system sold with signage and extinguisher for each doorway. Standard red illuminated sign on independent power source.20-lb minimum fire extinguisher and stand.
Lightning Protection SystemLightning system includes the required number of lightning rods for full shelter coverage. Rods attach to grounding cable. Secured with high strength clips to fabric patch.
Rope TethersUpgraded tetherstraps with a modified design featuring rope tethers. This improvement eliminates "flapping" in extreme weather conditions. Should be considered in regularly occupied shelters. Cost is incremental of regular strap cost.
Anchoring SystemUpgraded anchors should be considered for poor soil conditions. Helical anchors ($70/ea) or other specialized anchors ($TBD/ea) may be required.Various

ADDITIONAL INFORMATION

Internal AreaInternal area of shelter7,395 ft2
Shelter EnvelopeGround stakes requires space on the sides and ends for ground staking.74 ft x 181 ft
Concrete blocks requires space on the sides and ends for concrete anchor blocks (not provided). Ensure enough space on site for maneuvering vehicle during block placement.77 ft x 178 ft
Tethermasts requires a small amount of space around the shelter, typically less than 7-ft / 2.13-m depending on design. Current designs include standard ballasted masts and reduced footprint masts.Approx. 79 ft x 170 ft
OccupancyOccupancy is based on 12 ft2 / 3.66 m2 per person.616 people
Electrical requiredPower required for recommended lights and blowers. Does not include HVAC.53 Amps
Wind LoadMinimum wind rating. If winds exceed this speed, Dynamic should be notified to confirm expected maximum wind speeds. In extreme hurricane winds, the shelter should be deflated and covered until winds return to normal wind speeds.80 mph
Snow LoadHigh natural snow load capacity, and capable of shedding extreme snow loads when shelter is heated.10-lbs/ft2 natural snow load capacity.
FabricsAll fabrics to National Fire Code NFPA 701 and ULC S109 (Canada).